Introduction
Any failure in sizing compromises both the plant’s regulatory compliance and its continuity of operation. Groupe Boët met this requirement by supplying two high-performance industrial silencers for the Trapani power plant in Sicily.
Trapani power plant: silencers for demanding conditions
As part of a plant construction project, the operator expressed the need for two acoustic silencers for the turbine, in a circuit conveying high-temperature hot air.
The operating conditions imposed were particularly severe: maximum inlet temperature of 271°C, outlet pressure open to atmosphere, and flange connection requirements in line with international ASME standards. This type of project requires complete mastery of aero-acoustic dimensioning and rigorously controlled manufacturing.
Turbine noise control: the technical challenges
Noise abatement on a gas turbine in service poses specific technical constraints. Silencers must provide effective sound attenuation while withstanding high temperatures, without generating pressure drops that penalize the circuit. Flanged connections must comply with strict dimensional tolerances to guarantee the sealing and mechanical strength of the assembly.
Solution: custom-designed DN200 silencers
In this context, Groupe Boët made a precise technical adaptation to the initial reference plan. The body material was modified – S235JR steel instead of the 16MO3 originally planned – after customer approval. The assembly flange was redefined in compliance with ASME B16.5, with tight control of dimensional tolerances to remain within the envelope specified by the operator.
Silencer
Groupe Boët has designed and manufactured two DN200 industrial silencers, adapted to the GT9E turbine construction plan. Each unit has a total length of 1,500 mm, a unit weight of 165 kg, and surface protection by high-temperature black paint, adapted to the thermal conditions of the installation.
The choice of silencers with absorbing elements meets the need to combine effective noise reduction at the frequencies characteristic of gas turbines, while maintaining low aeraulic resistance. The design incorporates a BSPP drain with plug, enabling purging and maintenance during operation.
Specifications and certified manufacturing
The acoustic equipment was manufactured in Groupe Boët’s workshops in Tourcoing, within the framework of an ISO 9001 and ISO 19443 certified management system. The silencers comply with the main applicable construction codes and standards: ASME B16.5 for flanged assemblies, as well as RCC-M, CODAP and CODETI according to project requirements.
The contractually agreed manufacturing lead time is eleven weeks from receipt of order, with delivery from Tourcoing. The warranty covers material and manufacturing defects for twelve months after commissioning. This level of commitment reflects the industrial rigor applied by Groupe Boët to all its acoustic silencers for the energy industry.
Internationally recognized expertise in industrial silencers
This project illustrates Groupe Boët’s ability to intervene in energy production applications with high technical constraints, by adapting its industrial acoustic solutions to the precise specifications of each installation. From the sizing phase to certified manufacturing, each stage is carried out with the same rigorous engineering standards.
To submit a requirement for industrial silencers or noise reduction for turbines, compressors or power units, contact Groupe Boët for a customized technical analysis.